Death Trap 5 of 5
| |
|
This one was wired up correctly.
Brown is the hot wire, blue is neutral.
I didn't fake the image, I only increased the contrast around the letters.
---
ALWAYS TURN OFF THE MAINS POWER IN THE BREAKER-PANEL BEFORE YOU STICK YOUR FINGERS IN. MAKE SURE IT STAYS OFF!
Death Trap 4 of 5
| |
|
This one was NOT wired up correctly.
Brown is the hot wire, blue is neutral. But what do we find? Brown --> N, Blue --> L
Why is this bad? Screwing in a light bulb puts you in danger of getting a shock, as the hot wire is connected to the large metal part of the E27 of the light bulb first. Initially that part is partially exposed. Not good.
I didn't fake the image, I only increased the contrast around the letters.
---
ALWAYS TURN OFF THE MAINS POWER IN THE BREAKER-PANEL BEFORE YOU STICK YOUR FINGERS IN. MAKE SURE IT STAYS OFF!
Death Trap 3 of 5
| |
|
Now which of these two contacts should be "hot" ?
The one at the very back, right?
---
ALWAYS TURN OFF THE MAINS POWER IN THE BREAKER-PANEL BEFORE YOU STICK YOUR FINGERS IN. MAKE SURE IT STAYS OFF!
Death Trap 2 of 5
| |
|
Checking the wiring going into the lamp fixture. All OK up there.
---
ALWAYS TURN OFF THE MAINS POWER IN THE BREAKER-PANEL BEFORE YOU STICK YOUR FINGERS IN. MAKE SURE IT STAYS OFF!
Death Trap 1 of 5
| |
|
Looks good, but is it?
---
ALWAYS TURN OFF THE MAINS POWER IN THE BREAKER-PANEL BEFORE YOU STICK YOUR FINGERS IN. MAKE SURE IT STAYS OFF!
LED-strip + custom controller
| |
|
LED-strip + custom controller
| |
|
Power supply - load test
Power supply - load test
DMM A/D
| |
|
No external fuse access ;-(
| |
|
I've blown this fuse again. One reason might be that I use 160mA ones instead of 500mA. Why? I have one, but not the other.
Is that really copper?
| |
|
I tried to twist the strands together. They immediately sprung back. They're very flexible, but too springy.
Supposedly 0.5mm² of copper
| |
|
Hmmmm.
Each wire has about 20 strands. Diameter 80µm. There's just NO WAY that adds up to 0.5mm². Depending on how I calculate the cross section (multiply strand cross section vs. measure wire diameter with air gaps), I end up with values between 0.005mm² and 0.15mm² - NOT ENOUGH.
That cable is too thin for 16A
16A... sure...
| |
|
You need ad least 1.5mm² to handle 16A safely. 0.5mm² is simply not enough! But does the actually have 0.5mm² of copper inside? Let's check!