Death Trap 5 of 5

18 May 2013 192
This one was wired up correctly. Brown is the hot wire, blue is neutral. I didn't fake the image, I only increased the contrast around the letters. --- ALWAYS TURN OFF THE MAINS POWER IN THE BREAKER-PANEL BEFORE YOU STICK YOUR FINGERS IN. MAKE SURE IT STAYS OFF!

Death Trap 4 of 5

18 May 2013 239
This one was NOT wired up correctly. Brown is the hot wire, blue is neutral. But what do we find? Brown --> N, Blue --> L Why is this bad? Screwing in a light bulb puts you in danger of getting a shock, as the hot wire is connected to the large metal part of the E27 of the light bulb first. Initially that part is partially exposed. Not good. I didn't fake the image, I only increased the contrast around the letters. --- ALWAYS TURN OFF THE MAINS POWER IN THE BREAKER-PANEL BEFORE YOU STICK YOUR FINGERS IN. MAKE SURE IT STAYS OFF!

Death Trap 3 of 5

18 May 2013 172
Now which of these two contacts should be "hot" ? The one at the very back, right? --- ALWAYS TURN OFF THE MAINS POWER IN THE BREAKER-PANEL BEFORE YOU STICK YOUR FINGERS IN. MAKE SURE IT STAYS OFF!

Death Trap 2 of 5

18 May 2013 191
Checking the wiring going into the lamp fixture. All OK up there. --- ALWAYS TURN OFF THE MAINS POWER IN THE BREAKER-PANEL BEFORE YOU STICK YOUR FINGERS IN. MAKE SURE IT STAYS OFF!

Death Trap 1 of 5

18 May 2013 193
Looks good, but is it? --- ALWAYS TURN OFF THE MAINS POWER IN THE BREAKER-PANEL BEFORE YOU STICK YOUR FINGERS IN. MAKE SURE IT STAYS OFF!

LED-strip + custom controller

LED-strip + custom controller

Power supply - load test

17 May 2013 169
Testing the power supply that came with my LED strip. Made with gnuplot.

Power supply - load test

17 May 2013 211
Testing the power supply that came with my LED strip.

DMM A/D

No external fuse access ;-(

17 May 2013 192
I've blown this fuse again. One reason might be that I use 160mA ones instead of 500mA. Why? I have one, but not the other.

Is that really copper?

17 May 2013 189
I tried to twist the strands together. They immediately sprung back. They're very flexible, but too springy.

Supposedly 0.5mm² of copper

17 May 2013 200
Hmmmm. Each wire has about 20 strands. Diameter 80µm. There's just NO WAY that adds up to 0.5mm². Depending on how I calculate the cross section (multiply strand cross section vs. measure wire diameter with air gaps), I end up with values between 0.005mm² and 0.15mm² - NOT ENOUGH.

That cable is too thin for 16A

17 May 2013 158
...and much worse inside.

16A... sure...

17 May 2013 168
You need ad least 1.5mm² to handle 16A safely. 0.5mm² is simply not enough! But does the actually have 0.5mm² of copper inside? Let's check!

16A... sure...

17 May 2013 168
The plug itself might handle 16A, but not the cable that was attached to it.

Good IEC plug

17 May 2013 153
A much better fit, less wiggle.

BAD IEC plug

17 May 2013 174
The power supply itself seems quite decent, but the cable / plug... not so.